The cables are used as connecting cables to transmit digital signals inside railway rolling stocks.
4 cores | 10 mm² stranded tinned copper conductor with LSZH insulation. |
Combined Element | 3 cores (with Cu-strand 2 x 6mm², 1 x 2.5mm²) are twisted with a filling element to a combined element. |
Core Wrapping | Overlapped plastic-foil(s) |
Elements sheaths | TPE |
UIC Data Bus 0.75mm² | Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to a pair. |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Elements sheaths | TPE |
Core Wrapping | Overlapped plastic-foil(s) |
Stranding | 4 strands are twisted to a core together with 3 cored element, the UIC data bus and two fillers |
Core Wrapping | Overlapped plastic-foil(s) |
Outer Sheath | Cross-linked oil resistant LSZH compound |
4 cores | 10 mm² stranded tinned copper conductor with LSZH insulation |
Combined Element | 5 cores (with Cu-strand 2 x 6mm², 1 x 2.5mm² and 2 x 1.0 mm²) are twisted with a filling element to form a combined element. |
Core Wrapping | Overlapped plastic-foil(s) |
Elements sheaths | TPE |
UIC Data Bus 0.75mm² | Two foam PE or foam skin insulated tinned copper r stranded conductors are twisted together with two filling elements to a pair |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Elements sheaths | TPE |
Core Wrapping | Overlapped plastic-foil(s) |
Stranding | 4 strands are twisted to a core together with 5 cored element, the UIC data bus and two fillers |
Core Wrapping | Overlapped plastic-foil(s) |
Outer Sheath | Cross-linked oil resistant LSZH compound |
Star Quad | Four LSZH insulated 1mm² stranded tinned copper conductors are twisted to form a star quad |
UIC Data Bus 0.75mm² | Two foam PE or foam skin insulated tinned copper stranded conductors are twisted together with two filling elements to form a pair |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Elements sheaths | TPE |
Core Wrapping | Overlapped plastic-foil(s) |
Stranding | 4 star quads are stranded together with 2 or 4 UIC data bus cable and several fillers |
Core Wrapping | Overlapped plastic-foil(s) |
Screen | Tin plated copper braid |
Outer Sheath | Cross-linked oil resistant LSZH compound |
Nominal Voltage | 300V |
Maximum Temperature | 90°C |
Minimum Temperature | -40°C |
Bending Radius | 12 x Overall Diameter |
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali |
EN 50305 | Resistance to ozone |
EN 50306-2 | Hazard levels HL1, HL2, HL3 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | F0 |
EN54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 |
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity |
NF F 63 808; BS6853; NF F 16 101 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 25 | 917 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
10 | 80/0.4 | 1.95 | - | - | - | - | - | |||
6 | 84/0.3 | 3.39 | - | - | - | - | - | |||
2.5 | 37/0.29 | 8.21 | - | - | - | - | - |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 25 | 969 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
10 | 80/0.4 | 1.95 | - | - | - | - | - | |||
6 | 84/0.3 | 3.39 | - | - | - | - | - | |||
2.5 | 37/0.29 | 8.21 | - | - | - | - | - |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 18.5 | 498 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
1 | 19/0.25 | 20 | - | - | - | - | - |
Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | |||
---|---|---|---|---|---|---|---|---|---|---|
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm² | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.5 | 23 | 530 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
1 | 19/0.25 | 20 | - | - | - | - | - |