-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
| Conductor | Tinned annealed copper wires as defined in EN 50306-2 | 
| Insulation | LSZH special compound | 
| Overal Screen | Tinned annealed copper wires | 
| Outer Sheath | LSZH special compound (S1 & S2) | 
| Nominal Voltage | 300/500 V | 
| Max. Conductor Temperature | 90°C /105°C (fixed installation) | 
| Min. Permissible Ambient Temperature | -25°C/-40°C (fixed installation) | 
| Bending Radius | Fixed installation: 3 x Overall Diameter (D<12mm); 4 x Overall Diameter (D>12mm) Flexible installation: 5 x Overall Diameter (D<12mm); 6 x Overall Diameter (D>12mm)  | 
| EN 60684-2 | No fluorine | 
| EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali | 
| EN 50305 | Resistance to ozone | 
| EN 50306-2 | Hazard levels HL1, HL2, HL3 | 
| DIN 5510-2 | Protection level 1/2/3/4 | 
| BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II | 
| NF F 16-101 | F0 | 
| EN54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 | 
| EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable | 
| EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables | 
| EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission | 
| EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free | 
| EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) | 
| EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity | 
| NF F 63 808; BS6853; NF F 16 101 | Smoke index | 
| EN45545-2 | Requirement for fire behavior of materials & components R15/R16 | 
| Number of Cores x Nominal Cross Section | Min. Thickness of Sheath at any Point | Overall Diameter | Weight | |
|---|---|---|---|---|
| Min. | Max. | |||
| n x mm² | mm | mm | mm | kg/km | 
| 2 x 0.5 | 0.20 | 3.5 | 4.3 | 28 | 
| 3 x 0.5 | 0.20 | 3.7 | 4.5 | 35 | 
| 4 x 0.5 | 0.20 | 4.0 | 5.0 | 40 | 
| 2 x 0.75 | 0.20 | 3.9 | 4.7 | 35 | 
| 3 x 0.75 | 0.20 | 4.0 | 5.0 | 40 | 
| 4 x 0.75 | 0.20 | 4.5 | 5.5 | 60 | 
| 2 x 1 | 0.20 | 4.2 | 5.2 | 40 | 
| 3 x 1 | 0.20 | 4.5 | 5.5 | 55 | 
| 4 x 1 | 0.20 | 5.0 | 6.0 | 70 | 
| 2 x 1.5 | 0.20 | 5.1 | 6.1 | 60 | 
| 3 x 1.5 | 0.20 | 5.4 | 6.4 | 80 | 
| 4 x 1.5 | 0.20 | 6.0 | 7.0 | 100 | 
| 2 x 2.5 | 0.20 | 6.4 | 7.4 | 90 | 
| 3 x 2.5 | 0.20 | 6.8 | 7.8 | 120 | 
| 4 x 2.5 | 0.20 | 7.5 | 8.5 | 140 | 
                
            