Thin Wall Multipair Individually Screened and Sheathed Cables with Standard Wall Overall Sheath
APPLICATION-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.-Used in cable harnesses, switchboards and control panels, driver desks etc.CONS…
EN 50306-4 Thin Wall Multipair Individually Screened Cables, With Overall Screen & Standard Wall Sheath.pdf Contact us

APPLICATION

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

CONSTRUCTION

ConductorTinned annealed copper wires as defined in EN 50306-2
InsulationLSZH special compound
Pair ScreenIndividual screened and sheathed; Screened according to EN 50306-3; Sheathed according to EN 50306-3 (S1. S2)
Pair IdentificationPairs numbered according to EN 50306-4
Outer SheathLSZH special compound (S2. EM 101 - EM 104)

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage300/500 V
Max. Conductor Temperature90°C /105°C (fixed installation)
Min. Permissible Ambient Temperature-25°C/-40°C (fixed installation)
Bending Radius10 x Overall Diameter

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0
EN54454-2R15 Interior/ R16 Exterior HL1, HL2, HL3

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN45545-2Requirement for fire behavior of materials & components R15/R16

BRAIL TW-05MP-SW-IS 300/500V

Number of Cores x Nominal Cross SectionMin. Thickness of Sheath at any PointOverall DiameterWeight
Min.Max.
n x mm²mmmmmmkg/km
2 x 2 x 0.50.569.010.290
3 x 2 x 0.50.569.610.8120
4 x 2 x 0.50.5610.711.9160
7 x 2 x 0.50.5613.014.2240

2 x 2 x 0.750.569.811.090
3 x 2 x 0.750.5610.511.7150
4 x 2 x 0.750.5611.612.8180
7 x 2 x 0.750.5614.015.6290

2 x 2 x 1.00.5610.211.6110
3 x 2 x 1.00.5610.912.1160
4 x 2 x 1.00.5612.113.3200
7 x 2 x 1.00.5614.616.2330

2 x 2 x 1.50.5612.213.4150
3 x 2 x 1.50.5613.114.3230
4 x 2 x 1.50.5614.315.9290
7 x 2 x 1.50.5617.619.2490