APPLICATION AND DESCRIPTION
The two-conductor Interbus-Loop cable is to be applied as a data transmission cable as well as for the supply of sensors. The three-conductor Interbus-Loop cables is applied for supply of actuators. These cables are also suitable for Interbus-Loop 2.
CONSTRUCTION
| Type | 2 pairs/ 3 pairs interbus Loop cable | 
| Inner Conductor | Bare copper conductors 1.5mm^2 | 
| Conductor Insulation | PE | 
| Stranding Element | Specially adjusted layering with netting tape and one additional nonwoven tape over the outer layer | 
| Core Wrapping | - | 
| Shielding | - | 
| Drain Wire: | - | 
| Outer Jacket Material | PVC/ PUR/ FRNC | 
| Conductor identification | Blue, red | 
| Sheath colour | Purple | 
| Outer Jacket Color | Yellow /Black | 
ELECTRICAL DATA
| Characteristic Impedance@250MHz - 10MHz | 75 Ω ± 15 Ω | 
| Radiation Resistance | 5 x 107 cJ/kg | 
| Weather Resistance | Very good | 
| Working Voltage | Max: 350V | 
| Test Voltage | 1KV | 
TECHNICAL DATA
| Weight: | approximately 78.0 kg/km | approximately 94.0 kg/km | 
| Min. Bending Radius | 15 x OD mm | 
| Operating Temp.Range, min. | - 40 °C(flexing)/ - 50 °C(static) | 
| Operating Temp.Range, max. | +90 °C |