Thin Wall Multicore Overall Screened Cables with Standard Wall Sheath 300/500 V
APPLICATION-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.-Used in cable harnesses, switchboards and control panels, driver desks etc.CONS…
EN 50306-4 Thin Wall Multicore Overall Screened Cables with Standard Wall Sheath.pdf Contact us

APPLICATION

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

CONSTRUCTION

ConductorTinned annealed copper wires as defined in EN 50306-2
InsulationLSZH special compound
Overal ScreenTinned annealed copper wires
Outer SheathLSZH special compound as defined in EN 50264-1 (S2. EM 101 - EM 104)

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage300/500 V
Max. Conductor Temperature90°C /105°C (fixed installation)
Min. Permissible Ambient Temperature-25°C/-40°C (fixed installation)
Bending Radius10 x Overall Diameter

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0
EN54454-2R15 Interior/ R16 Exterior HL1, HL2, HL3

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN45545-2Requirement for fire behavior of materials & components R15/R16

BRAIL TW-05M-SW-OS 300/500 V

Number of Cores x Nominal Cross SectionMin. Thickness of Sheath at any PointOverall DiameterWeight
Min.Max.
n x mm²mmmmmmkg/km
2 x 0.50.424.15.130
3 x 0.50.424.35.340
4 x 0.50.424.75.750
6 x 0.50.425.56.570
8 x 0.50.426.07.090

2 x 0.750.424.55.540
3 x 0.750.424.75.750
4 x 0.750.425.26.260
6 x 0.750.426.17.190
8 x 0.750.426.67.6110

2 x 1.00.424.75.750
3 x 1.00.425.16.060
4 x 1.00.425.56.580
6 x 1.00.426.67.6110
8 x 1.00.567.78.7140

2 x 1.50.425.76.770
3 x 1.50.426.07.090
4 x 1.50.426.67.6100
6 x 1.50.568.39.3160
8 x 1.50.568.910.1200

2 x 2.50.567.38.3100
3 x 2.50.567.78.7130
4 x 2.50.568.49.6160