APPLICATION
Specifically designed for the rail transit industry, it is an ideal choice for connecting train fixed components. This high-performance cable is widely used in locomotive communication systems, constructing a train communication network (TCN) based on the TCN standard, ensuring reliable transmission of train control, instrument, and diagnostic information.
CONSTRUCTION
| Conductor | Stranded tinned copper conductor according to IEC 60228 class 5 | 
| Insulation | Foam PE or foam skin PE | 
| Cable Element | Twisted pair | 
| Core Wrapping | Plastic tape(s) | 
| EMC Screen 1 | Aluminium clad polyester foil | 
| EMC Screen 2 | Tinned copper braid | 
| Outer Sheath | Cross-linked oil resistant LSZH compound | 
ELECTRICAL & MECHANICAL PROPERTIES
| Nominal Voltage | 300V | 
| Maximum Temperature | 90°C | 
| Minimum Temperature | -40°C | 
| Bending Radius | 12 x Overall Diameter | 
CHEMICAL & ENVIRONMENTAL PROPERTIE
| EN 60684-2 | No fluorine | 
| EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali | 
| EN 50305 | Resistance to ozone | 
FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION
| EN 50306-2 | Hazard levels HL1, HL2, HL3 | 
| DIN 5510-2 | Protection level 1/2/3/4 | 
| BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II | 
| NF F 16-101 | F0 | 
| EN54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 | 
FIRE PERFORMANCE IN GENERAL
| EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable | 
| EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables | 
| EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission | 
| EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815 | Halogen Free | 
| EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) | 
| EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853  | Low Toxicity | 
| NF F 63 808; BS6853; NF F 16 101 | Smoke index | 
| EN45545-2 | Requirement for fire behavior of materials & components R15/R16 | 
FRL-WTB/MVB-02Y(ST+C)H-1P20A
| Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Max. Conductor Resistance | Impedance | Max. Attenuation | 
|---|
| 20°C | @0.75-3MHz | @1MHz | @2MHz | 
|---|
| mm² | AWG | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | 
|---|
| 0.62 | 20 | 19/0.2 | 1.2 | 8.3 | 80 | 33.1 | 120+/-12 | 10 | 15 |