Thin Wall Multicore Overall Screened Cables 300/500 V
APPLICATION-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.-Used in cable harnesses, switchboards and control panels, driver desks etc.CONS…
EN 50306-3 Thin Wall Multicore Overall Screened Cables.pdf Contact us

APPLICATION

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

CONSTRUCTION

ConductorTinned annealed copper wires as defined in EN 50306-2
InsulationLSZH special compound
Overal ScreenTinned annealed copper wires
Outer SheathLSZH special compound (S1 & S2)

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage300/500 V
Max. Conductor Temperature90°C /105°C (fixed installation)
Min. Permissible Ambient Temperature-25°C/-40°C (fixed installation)
Bending Radius

Fixed installation:

3 x Overall Diameter (D<12mm);

4 x Overall Diameter (D>12mm)

Flexible installation:

5 x Overall Diameter (D<12mm);

6 x Overall Diameter (D>12mm)

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0
EN54454-2R15 Interior/ R16 Exterior HL1, HL2, HL3

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN45545-2Requirement for fire behavior of materials & components R15/R16

BRAIL TW-05M-OS 300/500 V

Number of Cores x Nominal Cross SectionMin. Thickness of Sheath at any PointOverall DiameterWeight
Min.Max.
n x mm²mmmmmmkg/km
2 x 0.50.203.54.328
3 x 0.50.203.74.535
4 x 0.50.204.05.040
2 x 0.750.203.94.735
3 x 0.750.204.05.040
4 x 0.750.204.55.560
2 x 10.204.25.240
3 x 10.204.55.555
4 x 10.205.06.070
2 x 1.50.205.16.160
3 x 1.50.205.46.480
4 x 1.50.206.07.0100
2 x 2.50.206.47.490
3 x 2.50.206.87.8120
4 x 2.50.207.58.5140