Thin Wall Single Core Unsheathed Cables 300/500 V
APPLICATION-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.-Used in cable harnesses, switchboards and control panels, driver desks etc.CONS…
EN 50306-2 Thin Wall Single Core Unsheathed Cables.pdf Contact us

APPLICATION

-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are an important factor.

-Used in cable harnesses, switchboards and control panels, driver desks etc.

CONSTRUCTION

ConductorTinned annealed copper wires as defined in EN 50306-2
InsulationLSZH special compound

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage300/500 V
Max. Conductor Temperature90°C /105°C (fixed installation)
Min. Permissible Ambient Temperature-25°C/-40°C (fixed installation)
Bending Radius

3 x Overall Diameter (fixed installation);

5 x Overall Diameter (flexible installation)

CHEMICAL & ENVIRONMENTAL PROPERTIE

EN 60684-2No fluorine
EN 50305; EN 60811-2-1Resistance to mineral oil & fuel oil, acid & alkali
EN 50305Resistance to ozone

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

EN 50306-2Hazard levels HL1, HL2, HL3
DIN 5510-2Protection level 1/2/3/4
BS 6853Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101F0
EN54454-2R15 Interior/ R16 Exterior HL1, HL2, HL3

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN45545-2Requirement for fire behavior of materials & components R15/R16

BRAIL TW-05SU 300/500 V

Nominal Cross-Sectional AreaNumber x Nominal Diameter of WireDiameterMin. Mean Thickness of InsulationOverall DiameterWeightConductor Resistance
Min.Max.Min.Max.20°C
mm²n x mmmmmmmmmmmmkg/kmΩ/km
0.519 x 0.180.800.950.181.151.45740.1
0.7537 x 0.16(a)1.001.150.181.351.65826.7
1.037 x 0.18(a)1.101.300.181.451.801020.0
1.537 x 0.23(a)1.451.650.221.952.302013.7
2.537 x 0.30(a)1.852.150.282.502.85258.21

(a) =This cable may be supplied in 19 strand conductor providing all product performance requirements in the specification are met.