The cables are designed in railways signalling networks, and are suitable for installation in ducts or laying directly into the ground.
Dlk 1.013.107y
Dlk 1.013.108y (for 1.4/1.8mm conductor H95 type)
Dlk 1.013.110y
Type CodesConductors: Solid annealed copper, 0.9, 1.4 or 1.8 mm nominal diameter.
Insulation: Solid polyethylene.
Stranding: Single conductors are helically stranded in concentric layers. Cables from 14 conductors on have two extra conductors of 0.5mm with perforated insulation (surveillance conductors).
Core Wrapping: Plastic tape(s) with overlapping.
Inner Sheath: Low density polyethylene.
Armouring: One layer of galvanized steel tape (0.2-0.3mm) or two layers of galvanized steel tapes (0.1mm).
Outer Sheath: Low density polyethylene.
AJ- outdoor cable with protection against inductive infl uences
2Y solid PE conductor insulation
2Y inner PE sheath
B steel tape armor
2Y outer PE sheath
S signal cable
LG layer stranding
H (n) operating capacity
Nominal Conductor Diameter | mm | 0.9 | 1.4 | 1.8 |
Maximum Conductor Resistance | Ω/km | 28.9 | 11.9 | 7.2 |
Minimum Insulation Resistance @500 V DC (1min) | MΩ.km | 10000 | 10000 | 10000 |
Maximum Conductor Capacitance @800Hz (AC) | nF/km | 115 | 145/95* | 145/95* |
Dielectric Strength, conductor to conductor (DC voltage 1min) | V | 3535 | 3535 | 3535 |
Surveillance Conductors | ||||
Loop resistance, maximum | Ω/km | 190 | 190 | 190 |
Insulation resistance | ||||
- dry cable core, minimum | MΩ.km | 1000 | 1000 | 1000 |
- wet cable core, maximum | KΩ.km | 30 | 30 | 30 |
Operating Voltage AC/DC | V | 420/600 | 420/600 | 420/600 |
Test Voltage@50 Hz 1 min | ||||
Core to Core | Veff | 2500 | 2500 | 2500 |
Core to Screen | Veff | 2500 | 2500 | 2500 |
*The value“ 95” is only for cables with 1.4/1.8mm conductors according to Dlk 1.013.108y.
Minimum Bending Radius: 10×OD
Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)
Cable Code | Number of conductors (n) | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km | |
---|---|---|---|---|---|
Inner | Outer | ||||
0.9mm Conductor, 1.55mm Insulated Wire | |||||
RS107y-2Y2YB2Y-2C0.9-S(H115) | 2 | 1.3 | 1.2 | 12.0 | 120 |
RS107y-2Y2YB2Y-4C0.9-S(H115) | 4 | 1.3 | 1.2 | 13.0 | 140 |
RS107y-2Y2YB2Y-7C0.9-S(H115) | 7 | 1.3 | 1.2 | 14.0 | 170 |
RS107y-2Y2YB2Y-10C0.9-S(H115) | 10 | 1.3 | 1.2 | 15.5 | 220 |
RS107y-2Y2YB2Y-14C0.9-S(H115) | 14 | 1.3 | 1.2 | 16.0 | 260 |
RS107y-2Y2YB2Y-20C0.9-S(H115) | 20 | 1.3 | 1.2 | 17.0 | 320 |
RS107y-2Y2YB2Y-24C0.9-S(H115) | 24 | 1.3 | 1.2 | 19.0 | 370 |
RS107y-2Y2YB2Y-30C0.9-S(H115) | 30 | 1.3 | 1.2 | 19.0 | 410 |
RS107y-2Y2YB2Y-40C0.9-S(H115) | 40 | 1.3 | 1.2 | 20.0 | 500 |
RS107y-2Y2YB2Y-50C0.9-S(H115) | 50 | 1.3 | 1.2 | 22.0 | 590 |
RS107y-2Y2YB2Y-60C0.9-S(H115) | 60 | 1.3 | 1.2 | 23.0 | 680 |
RS107y-2Y2YB2Y-80C0.9-S(H115) | 80 | 1.3 | 1.2 | 25.0 | 840 |
RS107y-2Y2YB2Y-100C0.9-S(H115) | 100 | 1.3 | 1.3 | 28.0 | 1020 |
RS107y-2Y2YB2Y-120C0.9-S(H115) | 120 | 1.3 | 1.3 | 29.0 | 1180 |
RS107y-2Y2YB2Y-140C0.9-S(H115) | 140 | 1.3 | 1.3 | 31.0 | 1360 |
Cable Code | Number of conductors (n) | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km | |
---|---|---|---|---|---|
Inner | Outer | ||||
1.4mm Conductor, 2.2mm Insulated Wire | |||||
BR107y-2Y2YB2Y-4C1.4-S(H145) | 4 | 1.3 | 1.2 | 14.0 | 190 |
BR107y-2Y2YB2Y-7C1.4-S(H145) | 7 | 1.3 | 1.2 | 15.5 | 260 |
BR107y-2Y2YB2Y-10C1.4-S(H145) | 10 | 1.3 | 1.2 | 18.0 | 340 |
BR107y-2Y2YB2Y-14C1.4-S(H145) | 14 | 1.3 | 1.2 | 19.0 | 420 |
BR107y-2Y2YB2Y-20C1.4-S(H145) | 20 | 1.3 | 1.2 | 21.0 | 550 |
BR107y-2Y2YB2Y-24C1.4-S(H145) | 24 | 1.3 | 1.2 | 22.0 | 630 |
BR107y-2Y2YB2Y-30C1.4-S(H145) | 30 | 1.3 | 1.2 | 23.0 | 750 |
BR107y-2Y2YB2Y-40C1.4-S(H145) | 40 | 1.3 | 1.2 | 25.0 | 940 |
BR107y-2Y2YB2Y-50C1.4-S(H145) | 50 | 1.3 | 1.3 | 28.0 | 1140 |
BR107y-2Y2YB2Y-60C1.4-S(H145) | 60 | 1.3 | 1.3 | 30.0 | 1320 |
1.8mm Conductor, 2.7mm Insulated Wire | |||||
BR107y-2Y2YB2Y-4C1.8-S(H145) | 4 | 1.3 | 1.2 | 15.5 | 250 |
BR107y-2Y2YB2Y-7C1.8-S(H145) | 7 | 1.3 | 1.2 | 17.0 | 350 |
BR107y-2Y2YB2Y-10C1.8-S(H145) | 10 | 1.3 | 1.2 | 20.0 | 470 |
BR107y-2Y2YB2Y-14C1.8-S(H145) | 14 | 1.3 | 1.2 | 21.0 | 600 |
BR107y-2Y2YB2Y-20C1.8-S(H145) | 20 | 1.3 | 1.2 | 24.0 | 800 |
BR107y-2Y2YB2Y-24C1.8-S(H145) | 24 | 1.3 | 1.2 | 26.0 | 910 |
BR107y-2Y2YB2Y-30C1.8-S(H145) | 30 | 1.3 | 1.2 | 27.0 | 1100 |
BR107y-2Y2YB2Y-40C1.8-S(H145) | 40 | 1.3 | 1.2 | 30.0 | 1400 |
Cable Code | Number of conductors (n) | Nominal Sheath Thickness mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|---|---|---|---|
1.4mm Conductor, 2.7mm Insulated Wire | ||||
BR108y-2Y2Yv-10C1.4-S(H95) | 10 | 2.0 | 16.0 | 270 |
BR108y-2Y2Yv-14C1.4-S(H95) | 14 | 2.0 | 18.0 | 350 |
BR108y-2Y2Yv-20C1.4-S(H95) | 20 | 2.0 | 20.0 | 470 |
BR108y-2Y2Yv-30C1.4-S(H95) | 30 | 2.2 | 24.0 | 670 |
BR108y-2Y2Yv-50C1.4-S(H95) | 50 | 2.2 | 29.0 | 1050 |
1.8mm Conductor, 3.4mm Insulated Wire | ||||
BR108y-2Y2Yv-10C1.8-S(H95) | 10 | 2.0 | 19.0 | 400 |
BR108y-2Y2Yv-14C1.8-S(H95) | 14 | 2.2 | 21.0 | 540 |
BR108y-2Y2Yv-20C1.8-S(H95) | 20 | 2.2 | 24.0 | 730 |
BR108y-2Y2Yv-30C1.8-S(H95) | 30 | 2.2 | 28.0 | 1050 |
BR108y-2Y2Yv-50C1.8-S(H95) | 50 | 2.2 | 36.0 | 1700 |