APPLICATIONThe mission critical signalling cables are used between central signalling terminations frame and vital signalling equipments.STANDARDSE1047UNE 21031CABLE CONSTRUCTIONConductors : Solid tinned copper conductors.Insulation : PVC.Screen : TCW…
Concentric Signalling Cables Type 1 to SE1047.pdf Contact us

APPLICATION

The mission critical signalling cables are used between central signalling terminations frame and vital signalling equipments.

STANDARD

SE1047

UNE 21031

CABLE CONSTRUCTION

Conductors : Solid tinned copper conductors.

Insulation : PVC.

Screen : TCW (Tinned Copper Wire) screen.

Inner Sheath : PVC.

Outer Sheath : PVC.

Optional

Limited fire hazard concentric signalling cables : Stranded tinned copper conductors, XLPE insulation, TCW screen, PE sheath, units laid up, LFH sheath. (SE 1047 Type 2)

Concentric signalling screened cables : Stranded tinned copper conductors, PVC insulation, TCW spiral screen, PVC sheath, TCWB, units laid up, PVC sheath. (SE 1047 Type 3)

Limited fire hazard concentric signalling screened cables : Stranded tinned copper conductors, XLPE insulation, TCW spiral screen, PE sheath, TCWB, units laid up, LFH sheath. (SE 1047 Type 4)

Nominal Conductor Cross Sectionmm²1.85
Maximum DC Conductor ResistanceΩ/km11
Maximum DC Screen ResistanceΩ/km9.66

MECHANICAL AND THERMAL PROPERTIES

Minimum Bending Radius : 7.5×OD

Temperature Range : -25℃ to +85℃ (during operation); -10℃ to +70℃ (during installation)

DIMENSIONS AND WEIGHT

SE 1047 Type 1 Concentric Signalling PVC Sheathed Cables

Cable CodeNo. of units & Nominal Conductor Cross Sectional AreaNo. & Nominal Diameter of StrandsNominal Insulation ThicknessNominal Overall DiameterNominal Weight
No.×mm²No/mmmmmmkg/km
BRF1047-VC4VV-450/750V-1G1.851×1.851/1.530.710.9173
BRF1047-VC4VV-450/750V-3G1.853×1.851/1.530.718.4453
BRF1047-VC4VV-450/750V-7G1.857×1.851/1.530.723.9771
BRF1047-VC4VV-450/750V-19G1.8519×1.851/1.530.736.81815

SE 1047 Type 2 Concentric Signalling LFH Sheathed Cables

Cable CodeNo. of units & Nominal Conductor Cross Sectional AreaNo. & Nominal Diameter of StrandsNominal Insulation ThicknessNominal Overall DiameterNominal Weight
No.×mm²No/mmmmmmkg/km
BRF1047-RC4Z1Z1-450/750V-1G1.851×1.851/1.530.710.3140
BRF1047-RC4Z1Z1-450/750V-3G1.853×1.851/1.530.717.1361
BRF1047-RC4Z1Z1-450/750V-7G1.857×1.851/1.530.722.1612
BRF1047-RC4Z1Z1-450/750V-19G1.8519×1.851/1.530.733.81429

SE 1047 Type 3 Concentric Signalling Screened PVC Sheathed Cables

Cable CodeNo. of units & Nominal Conductor Cross Sectional AreaNo. & Nominal Diameter of StrandsNominal Insulation ThicknessNominal Overall DiameterNominal Weight
No.×mm²No/mmmmmmkg/km
BRF1047-VC4VC4V-450/750V-1G1.851×1.851/1.530.811.6210
BRF1047-VC4VC4V-450/750V-3G1.853×1.851/1.530.819.9561
BRF1047-VC4VC4V-450/750V-7G1.857×1.851/1.530.825.9987
BRF1047-VC4VC4V-450/750V-19G1.8519×1.851/1.530.840.22375

SE 1047 Type 4 Concentric Signalling Screened LFH Sheathed Cables

Cable CodeNo. of units & Nominal Conductor Cross Sectional AreaNo. & Nominal Diameter of StrandsNominal Insulation ThicknessNominal Overall DiameterNominal Weight
No.×mm²No/mmmmmmkg/km
BRF1047-RC4Z1C4Z1-450/750V-1G1.851×1.851/1.530.811.0184
BRF1047-RC4Z1C4Z1-450/750V-3G1.853×1.851/1.530.818.6487
BRF1047-RC4Z1C4Z1-450/750V-7G1.857×1.851/1.530.824.1875
BRF1047-RC4Z1C4Z1-450/750V-19G1.8519×1.851/1.530.837.22120