Standard Wall Single Core Unsheathed Cables (500V, 1000V, 1500V, 3000V)
APPLICATIONThese cables are used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor, suitable for use in control, auxiliary and main ci…
NF F 63-826 Standard Wall Single Core Unsheathed Cables 1500 V, 1000 V, 1500 V, 3000 V.pdf Contact us

APPLICATION

These cables are used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor, suitable for use in control, auxiliary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc

CONSTRUCTION

ConductorStranded tinned copper wires to IEC 60228 Class 5
InsulationSpecial halogen free compound

ELECTRICAL & MECHANICAL PROPERTIES

Nominal Voltage500V, 1000V, 1500V, 3000V
Max. Conductor Temperature90°C/105°C
Temperature Range-25°C~90°C
Bending Radius4 × Overall Diameter

FIRE PERFORMANCE FOR ROLLING STOCK APPLICATION

NF F 63-826

NF F 16-101

BS 6853

EN54454-2

FIRE PERFORMANCE IN GENERAL

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2)Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;  NF C 20-902; NF F 16 101; VDE 0472 Teil 816Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;  NF C 20-454; VDE 0472 Teil 815Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101Smoke index
EN45545-2Requirement for fire behavior of materials & components R15/R16

BRAIL SW-05SU 500 V

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Insulation ThicknessOverall DiameterWeight
Min.Max.
mm²No/mmmmmmmmkg/km
1.032/0.201.33.84.526
1.530/0.251.34.14.833
2.550/0.251.34.55.243
4.056/0.301.35.05.859
6.084/0.301.45.76.582
10.080/0.401.56.98.1135
16.0126/0.401.58.29.2210

BRAIL SW-1SU 1000V

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Insulation ThicknessOverall DiameterWeight
Min.Max.
mm²No/mmmmmmmmkg/km
1.530/0.251.54.45.242
2.550/0.251.54.8.5.655
4.056/0.301.55.46.272
6.084/0.301.66.16.996
10.080/0.401.67.08.3154
16.0126/0.401.68.39.4218
25.0196/0.401.79.811.0316
35.0276/0.401.811.212.5440
50.0396/0.401.913.014.3580
70.0360/0.502.014.716.3830
95.0475/0.502.016.618.41040
120.0608/0.502.118.620.51310

BRAIL SW-1.5SU 1500V

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Insulation ThicknessOverall DiameterWeight
Min.Max.
mm²No/mmmmmmmmkg/km
1.530/0.252.36.06.859
2.550/0.252.36.47.273
4.056/0.302.37.07.891
6.084/0.302.37.58.3120
10.080/0.402.38.49.7160
16.0126/0.402.39.710.8235
25.0196/0.402.311.012.2330
35.0276/0.402.412.413.7480
50.0396/0.402.514.215.5610
70.0360/0.502.716.117.7860
95.0475/0.502.718.019.81070
120.0608/0.502.820.021.91340
150.0756/0.502.821.823.81620
185.0925/0.502.923.725.91940
240.01221/0.503.126.629.12550
300.01525/0.503.4529.431.92950

BRAIL SW-3SU 3000V

Nominal Cross Sectional AreaNumber & Nominal Diameter of StrandsNominal Insulation ThicknessOverall DiameterWeight
Min.Max.
mm²No/mmmmmmmmkg/km
2.550/0.253.18.08.894
4.056/0.303.18.59.5124
6.084/0.303.18.89.9135
10.080/0.403.110.011.3200
16.0126/0.403.111.212.4265
25.0196/0.403.112.513.8375
35.0276/0.403.213.915.3493
50.0396/0.403.315.717.2680
70.0360/0.503.417.519.1930
95.0475/0.503.519.521.41066
120.0608/0.503.621.623.51530
150.0756/0.503.623.325.51740
185.0925/0.503.725.227.62100
240.01221/0.503.928.131.72460
300.01525/0.504.4531.435.03050