120 Ohm data transmission cables.
| Conductors | Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm²-1mm²). | 
| Insulation | Cross linked Foam PE. | 
| Cable Element | Twisted pair. | 
| Individual Screen | Individual Aluminium Tape. | 
| Overall Screen | Copper Wire Braid. | 
| Core Wrapping | Plastic tape(s). | 
| Outer Sheath | Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1. | 
| Conductor | Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm²-1mm²). | 
| Insulation | Cross linked Foam PE. | 
| Cable Element | Twisted pair. | 
| Overall Screen | Copper Wire Braid. | 
| Outer Sheath | Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1. | 
| Nominal Voltage | 300/500V | 
| Impedance | 120Ω+/-15% | 
| Capacitance@1KHz | 41nF/km | 
| Insulation Resistance | 5000MΩ | 
| EN 60684-2 | No fluorine | 
| EN 50305; EN 60811-2-1 | Resistance to mineral oil & fuel oil, acid & alkali | 
| EN 50305 | Resistance to ozone | 
| EN 50306-2 | Hazard levels HL1, HL2, HL3 | 
| DIN 5510-2 | Protection level 1/2/3/4 | 
| BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II | 
| NF F 16-101 | F0 | 
| EN54454-2 | R15 Interior/ R16 Exterior HL1, HL2, HL3 | 
| EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable | 
| EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 | Vertical flame spread of vertically mounted bunched wires or cables | 
| EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 | Low Smoke Emission | 
| EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 | Halogen Free | 
| EN 50267-2-2/3; IEC 60754-2; NF C 32-074; NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) | 
| EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 | Low Toxicity | 
| NF F 63 808; BS6853; NF F 16 101 | Smoke index | 
| EN45545-2 | Requirement for fire behavior of materials & components R15/R16 | 
| No.of pair x | Nominal Cross Sectional Area y | Number & Nominal Diameter of Strands | Nominal Overall Diameter | Nominal Weight | 
|---|---|---|---|---|
| mm² | No/mm | mm | kg/km | |
| 1 | 0.22 | 7/0.2 | 4.5 | 58 | 
| 2 | 0.22 | 7/0.2 | 6.2 | 79 | 
| 4 | 0.22 | 7/0.2 | 6.5 | 118 | 
| 1 | 0.5 | 16/0.2 | 6.6 | 79 | 
| 2 | 0.5 | 16/0.2 | 9.0 | 105 | 
| 4 | 0.5 | 16/0.2 | 9.8 | 145 | 
| 1 | 0.75 | 24/0.2 | 9.5 | 115 | 
| 2 | 0.75 | 24/0.2 | 10.3 | 135 | 
| 4 | 0.75 | 24/0.2 | 11.6 | 182 | 
| 1 | 1 | 30/0.2 | 11.5 | 125 | 
| 2 | 1 | 30/0.2 | 12.5 | 150 | 
| 4 | 1 | 30/0.2 | 13.5 | 180 | 
| No.of pair x | Nominal Cross Sectional Area y | Number & Nominal Diameter of Strands | Nominal Overall Diameter | Nominal Weight | 
|---|---|---|---|---|
| mm² | No/mm | mm | kg/km | |
| 1 | 0.22 | 7/0.2 | 4.2 | 55 | 
| 2 | 0.22 | 7/0.2 | 5.9 | 75 | 
| 4 | 0.22 | 7/0.2 | 6.2 | 115 | 
| 1 | 0.5 | 16/0.2 | 6.3 | 75 | 
| 2 | 0.5 | 16/0.2 | 8.5 | 100 | 
| 4 | 0.5 | 16/0.2 | 9.4 | 140 | 
| 1 | 0.75 | 24/0.2 | 9.0 | 110 | 
| 2 | 0.75 | 24/0.2 | 9.7 | 130 | 
| 4 | 0.75 | 24/0.2 | 11.1 | 178 | 
| 1 | 1 | 30/0.2 | 11.0 | 120 | 
| 2 | 1 | 30/0.2 | 12.0 | 145 | 
| 4 | 1 | 30/0.2 | 13.0 | 175 | 
                
            